Welcome to Shenzhen Powerlink electronic technology co.,ltd
MTP/MPO-4LC Duplex 9/125 Single-mode Fiber Optic Harness Fan-out/Breakout Cable, 8 Fiber, Polarity B, Female, LSZH-Yellow, Bunch, 40G PLRL4 PSM Interconnect Solution MTP/MPO Trunk Cable Fiber Optic Patch Cord,Fiber Optic Patch Cables
  • MTP/MPO-4LC Duplex 9/125 Single-mode Fiber Optic Harness Fan-out/Breakout Cable, 8 Fiber, Polarity B, Female, LSZH-Yellow, Bunch, 40G PLRL4 PSM Interconnect Solution MTP/MPO Trunk Cable Fiber Optic Patch Cord,Fiber Optic Patch Cables
  • MTP/MPO-4LC Duplex 9/125 Single-mode Fiber Optic Harness Fan-out/Breakout Cable, 8 Fiber, Polarity B, Female, LSZH-Yellow, Bunch, 40G PLRL4 PSM Interconnect Solution MTP/MPO Trunk Cable Fiber Optic Patch Cord,Fiber Optic Patch Cables
MTP/MPO-4LC Duplex 9/125 Single-mode Fiber Optic Harness Fan-out/Breakout Cable, 8 Fiber, Polarity B, Female, LSZH-Yellow, Bunch, 40G PLRL4 PSM Interconnect Solution MTP/MPO Trunk Cable Fiber Optic Patch Cord,Fiber Optic Patch Cables
‐Brief /

0.75dB IL, 2.0mm Fan-Out Diameter & 0.5m Breakout Length, 3.0mm Cable Jacket, designed for 40G LR4 PSM, 40G QSFP+ PLR4 and high-density data center

Connector type: FC, SC, LC, ST, MTRJ, MU, E2000, MPO, DIN, D4, SMA

Ferrule End-face: PC, UPC, APC 
Core Type: Single-mode (SM: 9/125um), Multimode (MM: 50/125um or 62.5/125um)
∠ Cable Quantity: ^2C ̄ means two cores=Duplex , 1C means one cores=Simplex
⊥ Cable Diameter: Ф3.0mm, Ф2.0mm, Ф0.9mm
⌒ Cable Length: 1, 2, 3 meter or customized

∂ Cable type: PVC, LSZH, OM3, OFNR, OFNP, Plenum

‐Series/MTP MPO Fiber patch cord
Description

MTP/MPO-4LC Duplex 9/125 Single-mode Fiber Optic Harness Fan-out/Breakout Cable, 8 Fiber, Polarity B, Female, LSZH-Yellow, Bunch, 40G PLRL4 PSM Interconnect Solution MTP/MPO Trunk Cable Fiber Optic Patch Cord,Fiber Optic Patch Cables

8 Fibers, 50um 10G OM4 Fiber, MTP to MTP, 12 Strands - MTP Backbone Trunk Cable
MTP is the high dense degree of optical fiber pre-connect system,which is generally use in three areas.
The Data Center application with high dense degree environment
The optical fiber to the building
The internal connector application in fiber equipment.
Powerlink's MTP fiber patch cable is compliant to IEC-61754-7 and TIA-604-5 standard. It can be widely used forPowerlinkpdf_d.png10G upgrade to 40G/100G data center.

Pre-terminated MTP Technology-Polarity Type B(Cross)

The application above is for the MTP-LC harness cable connecting a QSFP+port to(4)SFP+ports directly.
In many existing DC environments,LC-MTP cables are used to support high density fiber trunks between switches,rack patch panels and main distribution cabling panels(MDA).

For example:
Fs MTP_Technology-Polarity02.jpg
The above is the Eight-Fiber MTP-LC Assembly uses a pinless connector on one end for interfacing with the QSFP port on the Cisco Nexus 6000series,The other end contains four LC uniboot connectors,which provide connectivity to the SFP+ports on the switch.The polarity of the assembly pairs the fibers from the MTP Connector from the outside to the inside;thus,fiber 1 and fiber 12 are a duplex pair,as are fiber 2 and fiber 11,etc.


MTP Connector Types
FiberStore mpo_pic001.jpg FiberStore mpo_pic002.jpg
MTP Male with Pins MTP Female without Pins
MTP Male with Pins MTP Female without Pins
Two other clearly visible features are the noses and guide grooves (keys) on the top side.(Note: Female connector need to connect with male connector type.)
Pre-terminated MTP Technology-Polarity
The three polarity methods Type A, Type B and Type C are used to guarantee the right bi-directional allocation.
Please Note: When it is connected with two 40G QSFP+ transceivers, please choose the Type B Cross as polarity; when 
it is connected with other equipment such as MTP LGX Cassette, you can choose any of the polarities as you need.



Assembly Structure Illustration



The picture above is a 72 fibers trunk cable which is for your reference only.

MTP Trunk Fiber Patch Cables are terminated with MTP connector on both end.
1.The default diameter of the MTP cable is 3.0mm.
2.The default color of the single mode MTP connector is Blue.
3.The diameter of branch cable could be choose as 0.9mm,2.0mm,please kindly contact us at sales@fs.com for other diameter standard.
4.Powerlink can also custom the pulling eyes, welcome to contact us if you need.
MTP&MPO Difference

The term MTP is a registered trademark of US Conec, it has been the main trend in European and American areas.



MTP/MPO Machinery & Testing Equipment



1 Our adopt industry's leading high-performance polishing machine, and complemented by precision plates holders designed for MT ferrules.
2 The industry leading device of 3D interferometer provides verification of MTP/MPO polishing process, the interferometer making all parameters of hte polished MT ferrule complies and exceeds industry standards.
3 After the 3D interference detection, the flexibility of the tester provides the the complete spectrum of optical testing required for complex and high fiber count cable assemblies.
Fs fs-Machinery-Testing-Equipment-02.jpg
PreMTP/MPO-4LC Duplex 10G OM4 50/125 Multimode Fiber Optic Harness Fan-out/Breakout Cable, 8 Fiber, Polarity B, Female, Aqua, Bunch, 40GBASE-SR4 Interconnect Solution MTP/MPO Trunk Cable Fiber Optic Patch Cord,Fiber Optic Patch Cables
Next4 Fibers Single-mode Single Armor Single Jacket Central Loose Tube Waterproof Outdoor Fiber Optic Cable- GYXTW
Links
  • 2
  • 1
About us
Company Profile
Company Culture
Case
Case Categories 1
Case Categories 2
Case Categories 3
Case Categories 4
Case Categories 5
Products
WDM Optical Network
Fiber Optic Transceivers
Network Media Conversion
Fiber optic cable
Fiber Patch Cord&Pigtails
Cables Management
Contact us
Tel86-755-33160443
Fax86-755-22142476
E-mailinfo@powerlinksz.com
Address3nd Floor, 1st building, E block, MinZhu Western Industry Park, Shajing, Baoan Dist., Shenzhen, Guangdong, China